| Part # | Description | Notes | ||
| 19plus V2 | SEACATplus Version 2 PROFILER Pumped Conductivity, Temperature, Depth Recorder - Includes SBE 5M submersible pump, 64 MB memory, 6 differential A/D channels (0 - 5 volt input range), 1 RS-232 data input channel, data I/O & pump Y-cable (PN 17709), 2.5 meter data I/O cable (PN 801225), SEASOFT software, & complete documentation. Specify: housing (depth) & pressure sensor selections. Configurations that include pumped SBE 43 or other pumped auxiliary sensors require SBE 5T or 5P; see option 19p-4_. |
19plus V2 is intended primarily as a profiling CTD, sampling at 4 Hz, but can also be used in moored mode to obtain long-term time series data. 19plus V2 is powered by internal batteries, & records data in memory. In addition, in profiling mode, 19plus V2 can be deployed:
For photos of standard shipment, click here.
For other profiling CTDs, see SBE
9plus &
25. |
||
|
SBE 19plus V2 Housing (depth rating) Selections -- MUST SELECT ONE |
||||
| 19p-1a | 600 m plastic housing for CTD & SBE 5M plastic pump |
SBE 5M pump with plastic housing is rated to 600 m; SBE 5M pump with titanium housing is rated to 10,500 m. |
||
| 19p-1b | 7000 m titanium housing for CTD & SBE 5M titanium pump | |||
| SBE 19plus V2 Strain Gauge Pressure Sensor Selections -- MUST SELECT ONE (or select optional Digiquartz below) | ||||
| 19p-2a | 20 m strain gauge pressure sensor |
Pressure sensor is installed in connector end cap, & is not field replaceable / swappable. While highest
pressure rating gives you most flexibility in using 19plus
V2, it is at expense of
accuracy & resolution. It is advantageous to use lowest range
pressure sensor compatible with your intended maximum operating
depth, because accuracy & resolution are proportional to
pressure sensor's full scale range. For example, comparing 2000 &
7000 m sensors --
|
||
| 19p-2b | 100 m strain gauge pressure sensor | |||
| 19p-2c | 350 m strain gauge pressure sensor | |||
| 19p-2h | 600 m strain gauge pressure sensor | |||
| 19p-2d | 1000 m strain gauge pressure sensor | |||
| 19p-2e | 2000 m strain gauge pressure sensor | |||
| 19p-2f | 3500 m strain gauge pressure sensor | |||
| 19p-2g | 7000 m strain gauge pressure sensor | |||
|
SBE 19plus V2 Digiquartz Pressure Sensor (substitutes for strain gauge option) |
||||
| 19p-2i | 45 psia Digiquartz with temperature compensation |
Digiquartz pressure sensors provide better accuracy
(0.02% of full scale range vs 0.1% of full scale range) &
resolution than strain gauge pressure sensors. See SBE 19plus V2 Strain Gauge Pressure Sensor Options
above for photo of pressure sensor port; when used with Digiquartz,
plug is replaced with nylon pressure capillary fitting.Pressure sensor is installed in connector end cap, & is not field replaceable / swappable. While highest pressure rating gives you most flexibility in using 19plus V2, it is at expense of accuracy & resolution. It is advantageous to use lowest range pressure sensor compatible with your intended maximum operating depth, because accuracy & resolution are proportional to pressure sensor's full scale range. For example, comparing 2000 psia (1400 m) & 6000 psia (4200 m) sensors --
|
||
| 19p-2j | 100 psia Digiquartz with temperature compensation | |||
| 19p-2k | 200 psia Digiquartz with temperature compensation | |||
| 19p-2l | 300 psia Digiquartz with temperature compensation | |||
| 19p-2m | 400 psia Digiquartz with temperature compensation | |||
| 19p-2n | 1000 psia Digiquartz with temperature compensation | |||
| 19p-2o | 2000 psia Digiquartz with temperature compensation | |||
| 19p-2p | 3000 psia Digiquartz with temperature compensation | |||
| 19p-2q | 6000 psia Digiquartz with temperature compensation | |||
| 19p-2r | 10,000 psia Digiquartz with temperature compensation | |||
| 19p-2s | 15,000 psia Digiquartz with temperature compensation | |||
| SBE 19plus V2 Pump Option | ||||
| 19p-4a | Substitute SBE 5P plastic pump for SBE 5M plastic pump |
Standard
SBE
5M pump is intended for providing pumped conductivity only, for
improved conductivity response over a non-pumped system. Larger, more powerful SBE
5P or
5T is
required if also planning to pump auxiliary sensors (such as
dissolved oxygen, etc.).SBE 5P plastic pump is rated for 600 m; SBE 5T titanium pump is rated to 10,500 m. Operational characteristics of SBE 5P & 5T are identical. |
||
| 19p-4b | Substitute SBE 5T titanium pump for SBE 5M titanium pump | |||
|
SBE 19plus V2 Wet-Pluggable Connector Option |
||||
| 19p-5 | Substitute all Wet-pluggable (MCBH) connectors for Standard (XSG) connector (including SEACAT & pump bulkhead connectors, data I/O & pump Y-cable, & data I/O cable) |
Wet-pluggable connectors may be mated in wet
conditions. Their pins do not need to be dried before mating. By
design, water on connector pins is forced out as connector
is mated. However, they must not be mated or un-mated while
submerged. Wet-pluggable connectors have a non-conducting guide pin
to assist pin alignment & require less force to mate, making them
easier to mate reliably under dark or cold conditions, compared to
our standard (Impulse XSG/RMG) connectors. Like standard connectors,
wet-pluggables need proper lubrication & require care during use
to avoid trapping water in sockets.
19p-5 includes additional cost of wet-pluggable connectors on 19plus V2 & pump, data I/O & pump Y-cable with wet-pluggable connector on all three legs, & data I/O cable compatible with wet-pluggable data I/O connector. |
||
| SBE 19plus V2 Auxiliary Sensor & Integration Options | ||||
| 19p-6a | SBE 43 Dissolved Oxygen Sensor (Profiling Configuration), 7000 m (cable & mount included, requires option 19p-4a or -4b) |
General Information:
Sensor-Specific Information:
Moored Application Information:
|
||
| 19p-6b | SBE 43 Dissolved Oxygen Sensor (Profiling Configuration) with Wet-pluggable connector, 7000 m (cable & mount included, requires option 19p-4a or -4b & 19p-5) | |||
| 19p-6c | SBE 43 Dissolved Oxygen Sensor (Profiling Configuration), 600 m plastic (cable & mount included, requires option 19p-4a or -4b) | |||
| 19p-6d | SBE 43 Dissolved Oxygen Sensor (Profiling Configuration) with Wet-pluggable connector, 600 m plastic (cable & mount included, requires option 19p-4a or -4b & 19p-5) | |||
| 19p-7a | SBE 18 pH sensor for use in profiling mode only, 1200 m (cable & mount included) | |||
| 19p-7b | SBE 18 pH sensor for use in profiling mode only, with Wet-pluggable connector, 1200 m (cable & mount included – Requires option 19p-5) | |||
| 19p-8a | SBE 27 pH/ORP sensor for use in profiling mode only, 1200 m (cable & mount included) | |||
| 19p-8b | SBE 27 pH/ORP sensor for use in profiling mode only, with Wet-pluggable connector, 1200 m (cable & mount included – Requires option 19p-5) | |||
| YMOLD | Extra charge to substitute Y-cable to connect two (2) or more sensors to one (1) bulkhead connector | |||
| 19p-9a | Underwater power/data interface module (PDIM) integrated for use with SBE 36 CTD Deck Unit or 33 Carousel Deck Unit (includes PDIM, interface cable, & mounting hardware) |
SBE 36 CTD Deck Unit & PDIM provide surface power &
real-time data acquisition & control for 19plus V2, allowing
deployment with 10,000 m long single-conductor sea cables. SBE
36 is installed on ship, while PDIM is mounted on or near 19plus
V2.
See SBE 36 description for more information on interface. SBE 33 Deck Unit is typically used to provide surface power & real-time data acquisition & control for 19plus V2 & SBE 32 (32, 32C, or 32SC) Carousel Water Sampler or SBE 55 ECO Water Sampler. However, it can be used with PDIM instead of Carousel or ECO to provide same functionality as SBE 36 & PDIM. PDIM housing is anodized aluminum, & is rated to 6800 m. PDIM connector type (standard or wet-pluggable) must match 19plus V2 connector type. 19p-9a & -9b do not include SBE 36 or 33 Deck Unit; order separately.
|
||
| 19p-9b | Underwater power/data interface module (PDIM) with Wet-pluggable connectors integrated for use with SBE 36 CTD Deck Unit or 33 Carousel Deck Unit (includes PDIM, interface cable, & mounting hardware – Requires option 19p-5) | |||
| SBE 19plus V2 Hardigg Shipping Case Option | ||||
| 19p-10 | Substitute Hardigg shipping case (AL4915-1105) for wood crate, for SBE 19plus V2 in optional cage |
Hardigg shipping case with custom foam inserts holds SBE 19plus V2 with auxiliary sensors in optional cage.
Price for 19p-10 reflects a credit for deletion of our standard wood crate. |
||
| SBE 19plus V2 Accessories | ||||
| 801269 | Stainless-steel protective cage, 40 in. (101 cm) tall (SEACATplus) |
Many
users purchase optional cage to protect system from damage during
deployment.
See document 67171 for installation details.
19plus V2 deployed with SBE
32 (full size)
Carousel Water Sampler requires a shorter cage, which is mounted
horizontally below carousel in Carousel extension stand. 19plus V2 deployed on SBE 32C (compact) or 32SC (subcompact) Carousel Water Sampler is mounted in bottle position on Carousel, & does not use cage. 19plus V2 deployed on SBE 55 ECO Water Sampler is mounted on mesh panel, & does not use cage. Note: This cage is for use with SBE 19plus or 19plus V2, but not with older SEACAT (SBE 19). |
||
| 801270 | Stainless-steel protective cage, 48 in. (123 cm) tall (SEACATplus with Digiquartz) | |||
| 801511 | 9 NiMH cells in rechargeable drop-in pack (10.8V/8 Ah) |
|
||
| 90504 | NiMH battery charger for 6, 9, or 12 cells / 8 Ah D-cell packs. Provides full recharge in 2 hours, includes AC power cord & battery charging cable | |||
| 801641 | 9 Ni-Cad cells in drop-in rechargeable pack (10.8V/4.4 Ah) |
|
||
| 90226 | Ni-Cad battery charger (90/240 VAC) for 6/9/12 cells (16 hour charger) | |||
| 50288 | SBE 19plus19plus V2 Moored Mode Conversion Kit -- anti-foulant holders & hardware for user conversion from profiling to moored mode configuration. AF24173 anti-foulant devices (PN 801542) are NOT included. Note: When installed on 19plus/19plus V2 at time of order, T-C Duct & related parts normally installed on profilers are provided as a separate Profiling Conversion Kit, PN 50345 (order 801542 anti-foulant devices separately, or PN 50288.1 Kit with anti-foulant devices) | 19plus V2 is intended primarily for use as profiling instrument, & does not come standard with anti-foulant device fittings. Conversion kit allows user to retrofit 19plus V2 with anti-foulant device fittings for moored applications. Anti-foulant device fittings attach to each end of conductivity cell. See document 67114. Only 1 conversion kit is needed per instrument; order replacement Anti-Foulant Devices as needed (see 19plus V2 Spares below). | ||
| 20163 | USB to 232 Serial (DB-9P) Adapter, IOGear GUC232A (connects computers with USB ports to RS-232 instruments) | Many newer PCs & laptop computers have USB port(s) instead of RS-232 serial port(s). USB serial adapter plugs into USB port, & allows a serial device to be connected through adapter. Multi-port adapters are available from other companies; see Application Note 68. | ||
| 31313 | Hardigg shipping case (AL4915-1105), for SBE 19plus/19plus V2 in optional cage |
Hardigg shipping case with custom foam inserts holds SBE 19plus V2 with auxiliary sensors in optional cage.
|
||
| Underwater Cable for Hand-Hauled, Real-Time Profiling (see Application Note 59 for proper use & limitations) | ||||
| 801150 | Load-bearing Data cable, Standard connector, w/ DB-9S, 30 m (100 ft) (DN 32284) |
These cables are for hand-hauling 19plus
V2 &
acquiring real-time data. Cables are not intended for static working
loads above 45 kg (100 lbs); working loads above 18 kg (40 lbs) may
be difficult to handle without winch. Minimum recommended cable bend
radius is 10 cm (4 in.) (e.g., 20 cm sheave block nominal diameter).
See Application Note 59:
A Load-Bearing Underwater Cable for Hand-Hauled, Real-Time Profiling. Select a cable with connector (standard XSG or wet-pluggable MCBH) to match your 19plus V2. |
||
| 801295 | Load-bearing Data cable, Standard connector, w/ DB-9S, 50 m (165 ft) (DN 32284) | |||
| 801140 | Load-bearing Data cable, Standard connector, w/ DB-9S, 61 m (200 ft) (DN 32284) | |||
| 801153 | Load-bearing Data cable, Standard connector, w/ DB-9S, 100 m (330 ft) (DN 32284) | |||
| 801301 | Load-bearing Data cable, Standard connector, w/ DB-9S, 126 m (415 ft) (DN 32284) | |||
| 801148 | Load-bearing Data cable, Standard connector, w/ DB-9S, 183 m (600 ft) (DN 32284) | |||
| 801371 | Load-bearing Data cable, Wet-pluggable, w/ DB-9S, 30 m (100 ft) (DN 32643) | |||
| 801372 | Load-bearing Data cable, Wet-pluggable, w/ DB-9S, 60 m (200 ft) (DN 32643) | |||
| 801337 | Load-bearing Data cable, Wet-pluggable, w/ DB-9S, 100 m (330 ft) (DN 32643) | |||
| 801338 | Load-bearing Data cable, Wet-pluggable, w/ DB-9S, 200 m (660 ft) (DN 32643) | |||
| SBE 19plus V2 Spares | ||||
| 50434 | SBE 16plus V2/19plus V2 Spares Kit (Standard connectors) - Complete support kit containing spare data I/O cable, connectors, dummy plugs, & other mechanical spares & maintenance items. | Order appropriate spares kit for connector type on 19plus V2: | ||
| 50435 | SBE 16plus V2/19plus V2 Spares Kit (Wet-pluggable connectors) - Complete support kit containing spare data I/O cable, connectors, dummy plugs, & other mechanical spares & maintenance items. | |||
| 50275 | SBE 19plus/19plus V2 magnetic switch assembly |
|
||
| 41124 | Battery cover/contact plate, replaces 80076.1 |
Cover
plate for alkaline batteries. |
||
| 801225 | Data I/O cable, Standard connector (RMG-4FS) w/ DB-9S, 2.4 m (DN 32421) | Data I/O cable connects to 4-pin end of pump-data I/O Y-cable. These test cables are used for setting up system & uploading data from memory after recovery. Applicable cable is included with 19plus V2; these are spares. | ||
| 801374 | Data I/O cable, Wet-pluggable (MCIL-4FS) w/ DB-9S, 2.4 m (DN 32715) | |||
| 801542 | AF24173 Anti-foulant Device (pair, bagged, labeled for shipping) (replaces PN 801347) |
Anti-foulant
devices are typically used when 19plus V2 is deployed on a
mooring, instead of as a profiling CTD. Use of Anti-foulant devices
requires installation of PN 50288 SBE 19plus/19plus V2 Moored Mode
Conversion Kit (see SBE 19plus V2 Accessories above); anti-foulant
devices fit into anti-foulant device cups at each end of
conductivity cell.Useful life varies, depending on several factors. We recommend that customers consider more frequent replacement when high biological activity & strong current flow (greater dilution of anti-foulant concentration) are present. Moored instruments in high growth & strong dilution environments have been known to obtain a few months of quality data, while drifters that operate in non-photic, less turbid deep ocean environments may achieve years of quality data. Experience may be strongest determining factor in specific deployment environments. |
||
| 17709 | Y-cable, Pump-Data I/O (DN 31551) | These Y-cables connect 6-pin data I/O - pump bulkhead connector to pump (2-pin leg) & to data I/O cable (4-pin leg). | ||
| 171883 | Y-cable, Pump-Data I/O, Wet-pluggable (DN 32896) | |||
| 50087 | Cell filler/storage device | For cleaning conductivity cell after each use & storing instrument between uses. See document 67043 & Application Note 2D: Instructions for Care and Cleaning of Conductivity Cells. | ||
| various | Plumbing spares | For air bleed valve & y-fitting, & assorted sizes of Tygon tubing, see SBE 5M Configuration Details. | ||
Product configuration options listing for all products
Additional cables, mount kits, and spares may be found at: Cables, Mount kits for Sea-Bird sensors, Mount kits for Third Party sensors, Spare parts
![]()
Last modified: 14 May 2008
Sea-Bird Home Phone: (+1) 425-643-9866 Fax: (+1) 425-643-9954 E-mail: seabird@seabird.com