Part # Description Notes
37SM MicroCAT C & T (pressure optional) Recorder with Serial interface & Memory - Includes 7000 m titanium housing, mooring clamp, 8 MB Flash memory, RS-232 interface, lithium battery (non-hazardous), AF24173 Anti-Foulant Devices, data I/O cable (801412), SEASOFT software, & complete documentation (data I/O cable may be deleted for credit). Quantity orders will be packed several instruments to a box & each box will contain one manual & one software CD-ROM. Single packing, with a manual & CD-ROM in each box, will be provided on request. Specify: mooring clamp wire size selection to match O.D. of wire jacket. There are 6 MicroCAT models (37-SM, SMP, SI, SIP, IM, & IMP). 37-SM MicroCAT includes:
  • Serial interface (RS-232 standard, RS-485 optional)
  • Memory (37-SM with firmware version > 3.0 have 8 MB memory instead of 2 MB)

For photos of standard shipment, click here.

See SBE 16plus V2 SEACAT for instrument with auxiliary sensor input capability.

SBE 37-SM Mooring Clamp Wire Size Selections (Specify clamp to match O.D. of mooring wire jacket) -- MUST SELECT ONE

37SM-1a Wire guide & mounting clamp for 1/4 in. diameter mooring wire Cable fits loosely through wire guide, & is clamped only at mounting clamp. See document 67094.

Thread for clamping to mooring cable:

  • 37SM-1a (1/4 in. diameter): 1/4-28 UNF
  • 37SM-1b (5/16 in. diameter): 5/16-24 UNF
  • 37SM-1c (3/8 in. diameter): 3/8-24 UNF
  • 37SM-1d (1/2 in. diameter): 9/16-12 UNC
  • 37SM-1e (6 mm diameter): 1/4-20 UNF
  • 37SM-1f (8 mm diameter): 5/16-24 UNF
  • 37SM-1g (10 mm diameter): 7/16 -14 UNF
  • 37SM-1h (12 mm diameter): 1/2-13 UNF
  • 37SM-1i (16 mm, 5/8 in. diameter): 5/8-18 UNF
37SM-1b Wire guide & mounting clamp for 5/16 in. diameter mooring wire
37SM-1c Wire guide & mounting clamp for 3/8 in. diameter mooring wire
37SM-1d Wire guide & mounting clamp for 1/2 in. diameter mooring wire
37SM-1e Wire guide & mounting clamp for 6 mm diameter mooring wire
37SM-1f Wire guide & mounting clamp for 8 mm diameter mooring wire
37SM-1g Wire guide & mounting clamp for 10 mm diameter mooring wire
37SM-1h Wire guide & mounting clamp for 12 mm diameter mooring wire
37SM-1i Wire guide & mounting clamp for 16 mm (5/8 in.) mooring wire
37SM-1j Alternative mounting - plastic brackets to provide through-bolt mounting to a flat surface See document 67096.
SBE 37-SM ShallowCAT Option -- Plastic (PET-P) Housing with 250 meter depth rating
37SM-2 Substitute 250 m plastic housing (credit) Substituting plastic housing for standard 7000 m titanium housing provides lower cost option for shallow deployments.
SBE 37-SM Pressure Sensor Range (Depth) Options
37SM-3a 20 m strain gauge pressure sensor Pressure sensor is installed in end cap, & is not field replaceable / swappable. While highest pressure rating gives you most flexibility in using 37-SM, it is at expense of accuracy & resolution. It is advantageous to use lowest range pressure sensor compatible with your intended maximum operating depth, because accuracy & resolution are proportional to pressure sensor's full scale range. For example, comparing 2000 & 7000 m sensors --
  • 2000 m sensor:
    initial accuracy = 2 m (= 0.1% * 2000 m),
    resolution = 0.04 m (= 0.002% * 2000 m)
  • 7000 m sensor:
    initial accuracy = 7 m (= 0.1% * 7000 m),
    resolution = 0.14 m (= 0.002% * 7000 m)
37SM-3b 100 m strain gauge pressure sensor
37SM-3c 350 m strain gauge pressure sensor
37SM-3h 600 m strain gauge pressure sensor
37SM-3d 1000 m strain gauge pressure sensor
37SM-3e 2000 m strain gauge pressure sensor
37SM-3f 3500 m strain gauge pressure sensor
37SM-3g 7000 m strain gauge pressure sensor

SBE 37-SM Alternate Serial Interface and Power Options

37SM-4 External Power input capability (power plus RS-232 serial on 4-pin connector) - 4-pin data I/O cable substituted for standard 3-pin data I/O cable Standard 37-SM includes RS-232 serial interface & internal power. This option provides external power input capability. Internal battery pack is diode-OR’d with external power source, so power is drawn from whichever voltage source is higher.
37SM-5 RS-485 (half duplex ONLY) serial interface (replaces RS-232 interface) with external power input capability (4-pin connector) - 4-pin data I/O cable substituted for standard 3-pin data I/O cable Two-wire, RS-485 interface provides communication with individual 37-SM or with all 37-SMs attached to RS-485 interface. This allows for coordination of sampling among many instruments. However, note that half-duplex communication is one-direction at a time (i.e., you cannot send commands & receive data at same time).
This option also provides external power input capability. Internal battery pack is diode-OR’d with external power source, so power is drawn from whichever voltage source is higher.
Note that RS-232 & RS-485 versions of 37-SM have separate manuals; see manual links at top of page.
SBE 37-SM Wet-Pluggable Connector Options
37SM-6a Substitute 3-pin Wet-pluggable (MCBH) I/O connector for Standard (XSG) connector (includes data I/O cable)

(shown with optional mounting clamp)

Wet-pluggable connectors may be mated in wet conditions. Their pins do not need to be dried before mating. By design, water on connector pins is forced out as connector is mated. However, they must not be mated or un-mated while submerged. Wet-pluggable connectors have a non-conducting guide pin to assist pin alignment & require less force to mate, making them easier to mate reliably under dark or cold conditions, compared to our standard (Impulse XSG/RMG) connectors. Like standard connectors, wet-pluggables need proper lubrication & require care during use to avoid trapping water in sockets.

Both 37SM-6 options include a data I/O cable compatible with wet-pluggable data I/O connector.

37SM-6b Substitute 4-pin Wet-pluggable (MCBH) I/O connector for Standard (XSG) connector (if option 37SM-4 or -5 specified) (includes data I/O cable)
SBE 37-SM Storm Shipping Case Option -- holds up to 4 MicroCATs
37SM-7 Substitute Storm shipping case (iM2950) for wood crate -- holds up to 4 MicroCATs Storm shipping case with custom foam inserts holds up to 4 MicroCATs of any type -- IMP, IM, SMP, SM, SIP, SI.
  • Injection molded case with HPX resin plastic body, recessed wheels, automatic pressure equalization valve, hinged push-button latches, fold-down padded handle, & O-ring seal. Meets airline luggage regulations.
  • Inner dimensions:
    29 x 18 x 10.5 inches (74 x 46 x 27 cm).
  • Outer dimensions:
    31.3 x 20.4 x 12.2 inches (80 x 52 x 31 cm).

Price for 37SM-7 reflects a credit for deletion of our standard wood crate.

SBE 37-SM Accessories and Spares
801542 AF24173 Anti-Foulant Device (pair, bagged, labeled for shipping) (replaces PN 801347) Anti-foulant devices fit into anti-foulant device cups at each end of conductivity cell. Anti-foulant devices included with standard shipment; these are spares.
Useful life varies, depending on several factors. We recommend that customers consider more frequent replacement when high biological activity & strong current flow (greater dilution of anti-foulant concentration) are present. Moored instruments in high growth & strong dilution environments have been known to obtain a few months of quality data, while drifters that operate in non-photic, less turbid deep ocean environments may achieve years of quality data. Experience may be strongest determining factor in specific deployment environments.
50243.1 Lithium battery set (contains 6 each PN 80981.1) One set of batteries is included with standard shipment; these are spares. Batteries are easily accessed by removing 2 screws from connector end cap & pulling out end cap. Shipping restrictions apply for lithium batteries; see SBE 37-SM manual (RS-232 or RS-485) & Lithium Battery Shipping Guidelines for details.
50087.1 Cell filler/storage device with hose barbs This kit includes a syringe & tubing assembly, & 2 anti-foulant device caps with hose barbs. Remove installed anti-foulant device cap(s) & replace them with caps with hose barbs for cleaning & storage only.
  • Cleaning instructions require use of syringe & tubing assembly at intake end of conductivity cell (requiring 1 barbed cap).
  • Storage instructions require looping Tygon tubing from end to end of conductivity cell (requiring 2 barbed caps).

Do not deploy MicroCAT with barbed anti-foulant device cap(s)!

801412 Data I/O cable (3-pin, no external power), RMG-3FS to DB-9S, 2.4 m (DN 32778) 801412 -- Included with standard shipment; this is spare.

801366 -- Included with standard shipment if 37SM-6a specified (3-pin wet-pluggable connector); this is spare.

801385 -- Included with standard shipment if 37SM-4 or -5 specified (4-pin connector with external power input capability); this is spare.

801206 -- Included with standard shipment if 37SM-4 or -5 & 37SM-6b specified (4-pin wet-pluggable connector with external power input capability); this is spare.

801366 Data I/O cable (3-pin, no external power), Wet-Pluggable, MCIL-3FS to DB-9S, 2.4 m (DN 32702)
801385 Data/Power interface cable, RMG-4FS to DB-9S & red/black twisted wire leads, 2.4 m (DN 32277)
801206 Data/Power interface cable, Wet-Pluggable, MCIL-4FS to DB-9S & red/black twisted wire leads, 2.4 m (DN 32366)
20163 USB to 232 Serial (DB-9P) Adapter, IOGear GUC232A (connects computers with USB ports to RS-232 instruments) Many newer PCs & laptop computers have USB port(s) instead of RS-232 serial port(s). USB serial adapter plugs into USB port, & allows a serial device to be connected through adapter. Multi-port adapters are available from other companies; see Application Note 68.
31632 Storm shipping case (iM2950) -- holds up to 4 MicroCATs Storm shipping case with custom foam inserts holds up to 4 MicroCATs of any type -- IMP, IM, SMP, SM, SIP, SI.
  • Injection molded case with HPX resin plastic body, recessed wheels, automatic pressure equalization valve, hinged push-button latches, fold-down padded handle, & O-ring seal. Meets airline luggage regulations.
  • Inner dimensions:
    29 x 18 x 10.5 inches (74 x 46 x 27 cm).
  • Outer dimensions:
    31.3 x 20.4 x 12.2 inches (80 x 52 x 31 cm).

 

Product configuration options listing for all products

Additional cables, mount kits, and spares may be found at: Cables, Mount kits for Sea-Bird sensors, Mount kits for Third Party sensors, Spare parts