Brochure/specifications
Manual (RS-232 or
RS-485)
Reference Sheet (RS-232
or
RS-485)
Note: We do not publish prices on the website. Please contact Sea-Bird [seabird@seabird.com
or (+1) 425-643-9866] for pricing.
| Part # | Description | Notes | ||
| 37SM | MicroCAT C & T (pressure optional) Recorder with Serial interface & Memory - Includes 7000 m titanium housing, mooring clamp, 8 MB Flash memory, RS-232 interface, lithium battery (non-hazardous), AF24173 Anti-Foulant Devices, data I/O cable (801412), SEASOFT software, & complete documentation (data I/O cable may be deleted for credit). Quantity orders will be packed several instruments to a box & each box will contain one manual & one software CD-ROM. Single packing, with a manual & CD-ROM in each box, will be provided on request. Specify: mooring clamp wire size selection to match O.D. of wire jacket. | There are 6 MicroCAT models
(37-SM, SMP,
SI, SIP,
IM, &
IMP). 37-SM
MicroCAT includes:
For photos of standard shipment, click here. See SBE 16plus V2 SEACAT for instrument with auxiliary sensor input capability. |
||
|
SBE 37-SM Mooring Clamp Wire Size Selections (Specify clamp to match O.D. of mooring wire jacket) -- MUST SELECT ONE |
||||
| 37SM-1a | Wire guide & mounting clamp for 1/4 in. diameter mooring wire |
Cable fits loosely through wire guide, & is clamped
only at mounting clamp. See document
67094.Thread for clamping to mooring cable:
|
||
| 37SM-1b | Wire guide & mounting clamp for 5/16 in. diameter mooring wire | |||
| 37SM-1c | Wire guide & mounting clamp for 3/8 in. diameter mooring wire | |||
| 37SM-1d | Wire guide & mounting clamp for 1/2 in. diameter mooring wire | |||
| 37SM-1e | Wire guide & mounting clamp for 6 mm diameter mooring wire | |||
| 37SM-1f | Wire guide & mounting clamp for 8 mm diameter mooring wire | |||
| 37SM-1g | Wire guide & mounting clamp for 10 mm diameter mooring wire | |||
| 37SM-1h | Wire guide & mounting clamp for 12 mm diameter mooring wire | |||
| 37SM-1i | Wire guide & mounting clamp for 16 mm (5/8 in.) mooring wire | |||
| 37SM-1j | Alternative mounting - plastic brackets to provide through-bolt mounting to a flat surface | See document 67096. | ||
| SBE 37-SM ShallowCAT Option -- Plastic (PET-P) Housing with 250 meter depth rating | ||||
| 37SM-2 | Substitute 250 m plastic housing (credit) | Substituting plastic housing for standard 7000 m titanium housing provides lower cost option for shallow deployments. | ||
| SBE 37-SM Pressure Sensor Range (Depth) Options | ||||
| 37SM-3a | 20 m strain gauge pressure sensor |
Pressure
sensor is installed in end cap, & is not field replaceable / swappable. While highest
pressure rating gives you most flexibility in using 37-SM, it is at expense of
accuracy & resolution. It is advantageous to use lowest range
pressure sensor compatible with your intended maximum operating
depth, because accuracy & resolution are proportional to
pressure sensor's full scale range. For example, comparing 2000 &
7000 m sensors --
|
||
| 37SM-3b | 100 m strain gauge pressure sensor | |||
| 37SM-3c | 350 m strain gauge pressure sensor | |||
| 37SM-3h | 600 m strain gauge pressure sensor | |||
| 37SM-3d | 1000 m strain gauge pressure sensor | |||
| 37SM-3e | 2000 m strain gauge pressure sensor | |||
| 37SM-3f | 3500 m strain gauge pressure sensor | |||
| 37SM-3g | 7000 m strain gauge pressure sensor | |||
|
SBE 37-SM Alternate Serial Interface and Power Options |
||||
| 37SM-4 | External Power input capability (power plus RS-232 serial on 4-pin connector) - 4-pin data I/O cable substituted for standard 3-pin data I/O cable | Standard 37-SM includes RS-232 serial interface & internal power. This option provides external power input capability. Internal battery pack is diode-OR’d with external power source, so power is drawn from whichever voltage source is higher. | ||
| 37SM-5 | RS-485 (half duplex ONLY) serial interface (replaces RS-232 interface) with external power input capability (4-pin connector) - 4-pin data I/O cable substituted for standard 3-pin data I/O cable |
Two-wire, RS-485 interface provides communication
with individual 37-SM or with all 37-SMs attached to RS-485
interface. This allows for coordination of sampling among many
instruments. However, note that half-duplex communication is
one-direction at a time (i.e., you cannot send commands & receive
data at same time). This option also provides external power input capability. Internal battery pack is diode-OR’d with external power source, so power is drawn from whichever voltage source is higher. Note that RS-232 & RS-485 versions of 37-SM have separate manuals; see manual links at top of page. |
||
| SBE 37-SM Wet-Pluggable Connector Options | ||||
| 37SM-6a | Substitute 3-pin Wet-pluggable (MCBH) I/O connector for Standard (XSG) connector (includes data I/O cable) |
Wet-pluggable connectors may be mated in wet conditions. Their pins do not need to be dried before mating. By design, water on connector pins is forced out as connector is mated. However, they must not be mated or un-mated while submerged. Wet-pluggable connectors have a non-conducting guide pin to assist pin alignment & require less force to mate, making them easier to mate reliably under dark or cold conditions, compared to our standard (Impulse XSG/RMG) connectors. Like standard connectors, wet-pluggables need proper lubrication & require care during use to avoid trapping water in sockets. Both 37SM-6 options include a data I/O cable compatible with wet-pluggable data I/O connector. |
||
| 37SM-6b | Substitute 4-pin Wet-pluggable (MCBH) I/O connector for Standard (XSG) connector (if option 37SM-4 or -5 specified) (includes data I/O cable) | |||
| SBE 37-SM Storm Shipping Case Option -- holds up to 4 MicroCATs | ||||
| 37SM-7 | Substitute Storm shipping case (iM2950) for wood crate -- holds up to 4 MicroCATs |
Storm
shipping case with custom foam inserts holds up to 4
MicroCATs of any type -- IMP, IM, SMP, SM, SIP, SI.
Price for 37SM-7 reflects a credit for deletion of our standard wood crate. |
||
| SBE 37-SM Accessories and Spares | ||||
| 801542 | AF24173 Anti-Foulant Device (pair, bagged, labeled for shipping) (replaces PN 801347) |
Anti-foulant
devices fit into anti-foulant device cups at each end of
conductivity cell. Anti-foulant devices included with standard
shipment; these are spares.Useful life varies, depending on several factors. We recommend that customers consider more frequent replacement when high biological activity & strong current flow (greater dilution of anti-foulant concentration) are present. Moored instruments in high growth & strong dilution environments have been known to obtain a few months of quality data, while drifters that operate in non-photic, less turbid deep ocean environments may achieve years of quality data. Experience may be strongest determining factor in specific deployment environments. |
||
| 50243.1 | Lithium battery set (contains 6 each PN 80981.1) |
One set of batteries is included with standard
shipment; these are spares. Batteries are easily accessed by
removing 2 screws from connector end cap & pulling out end cap.
Shipping restrictions apply for lithium batteries; see SBE 37-SM manual
(RS-232 or
RS-485)
&
Lithium Battery Shipping Guidelines
for details. |
||
| 50087.1 | Cell filler/storage device with hose barbs |
This kit includes a syringe & tubing assembly, & 2
anti-foulant device caps with hose barbs. Remove installed
anti-foulant device cap(s) & replace them with caps with hose barbs
for cleaning & storage only.
Do not deploy MicroCAT with barbed anti-foulant device cap(s)! |
||
| 801412 | Data I/O cable (3-pin, no external power), RMG-3FS to DB-9S, 2.4 m (DN 32778) |
801412 -- Included with standard shipment; this is spare. 801366 -- Included with standard shipment if 37SM-6a specified (3-pin wet-pluggable connector); this is spare. 801385 -- Included with standard shipment if 37SM-4 or -5 specified (4-pin connector with external power input capability); this is spare. 801206 -- Included with standard shipment if 37SM-4 or -5 & 37SM-6b specified (4-pin wet-pluggable connector with external power input capability); this is spare. |
||
| 801366 | Data I/O cable (3-pin, no external power), Wet-Pluggable, MCIL-3FS to DB-9S, 2.4 m (DN 32702) | |||
| 801385 | Data/Power interface cable, RMG-4FS to DB-9S & red/black twisted wire leads, 2.4 m (DN 32277) | |||
| 801206 | Data/Power interface cable, Wet-Pluggable, MCIL-4FS to DB-9S & red/black twisted wire leads, 2.4 m (DN 32366) | |||
| 20163 | USB to 232 Serial (DB-9P) Adapter, IOGear GUC232A (connects computers with USB ports to RS-232 instruments) | Many newer PCs & laptop computers have USB port(s) instead of RS-232 serial port(s). USB serial adapter plugs into USB port, & allows a serial device to be connected through adapter. Multi-port adapters are available from other companies; see Application Note 68. | ||
| 31632 | Storm shipping case (iM2950) -- holds up to 4 MicroCATs |
Storm
shipping case with custom foam inserts holds up to 4
MicroCATs of any type -- IMP, IM, SMP, SM, SIP, SI.
|
||
Product configuration options listing for all products
Additional cables, mount kits, and spares may be found at: Cables, Mount kits for Sea-Bird sensors, Mount kits for Third Party sensors, Spare parts
![]()
Last modified: 22 Apr 2008