Family | Model | Pressure Sensor/Range |
SEAPHOX V2 | 0 – none | |
1 – 20 m strain gauge | ||
2 – 100 m strain gauge |
Example: SEAPHOX.1 is a SeapHOx with 20 m strain gauge pressure sensor. See table below for description of each selection:
PART # | DESCRIPTION | NOTES | ||||||||||||||||||
SEAPHOX V2 |
|
|||||||||||||||||||
SeaPHOx Configuration Selections — MUST SELECT ONE | ||||||||||||||||||||
SEAPHOX.0 | SeapHOx™ V2 Ocean CT (no pressure sensor) + pH + DO sensor. Integrates the SeaFET (v 2.0) Ocean pH sensor with flow cell and the Sea-Bird SBE 37SMP-ODO MicroCAT C and T Recorder with Integrated SBE 63 Optical Dissolved Oxygen sensor (ODO) with titanium housing. 50 meter depth rating. All sensors using wet-pluggable (MCBH) connector. Includes SeapHOx integration kit (mount brackets, flow tube adapter, Y-cable, RS-232 programming cable, hardware). |
Pressure sensor is installed in MicroCAT end cap (behind mount clamp), & is not field replaceable / swappable. While highest pressure rating gives you most flexibility in using MicroCAT, it is at expense of accuracy & resolution. It is advantageous to use lowest range pressure sensor compatible with your intended maximum operating depth, because accuracy & resolution are proportional to pressure sensor's full scale range. For example, comparing 20 & 100 m sensors:
|
||||||||||||||||||
SEAPHOX.1 | SeapHOx™ V2 Ocean CTD + pH + DO sensor. Integrates the SeaFET (v 2.0) Ocean pH sensor with flow cell and the Sea-Bird SBE 37SMP-ODO MicroCAT CTD with 20 meter pressure sensor, with Integrated SBE 63 Optical Dissolved Oxygen sensor (ODO) with titanium housing. 20 meter depth rating. All sensors using wet-pluggable (MCBH) connector. Includes SeapHOx integration kit (mount brackets, flow tube adapter, Y-cable, RS-232 programming cable, hardware). | |||||||||||||||||||
SEAPHOX.2 | SeapHOx™ V2 Ocean CTD + pH + DO sensor. Integrates the SeaFET (v 2.0) Ocean pH sensor with flow cell and the Sea-Bird SBE 37SMP-ODO MicroCAT CTD with 100 meter pressure sensor, with Integrated SBE 63 Optical Dissolved Oxygen sensor (ODO) with titanium housing. 50 meter depth rating. All sensors using wet-pluggable (MCBH) connector. Includes SeapHOx integration kit (mount brackets, flow tube adapter, Y-cable, RS-232 programming cable, hardware). | |||||||||||||||||||
SBE 37-SMP Mooring Clamp Wire Size Selections (Specify clamp to match O.D. of mooring wire jacket; cannot accommodate wire size greater than 1.2 in. diameter) — MUST SELECT ONE | ||||||||||||||||||||
50465.I | Wire guide & mounting clamp for 1/4 in. diameter mooring wire |
Cable fits loosely through wire guide, & is clamped only at mounting clamp. See document 67219. '.I' designation indicates that guide and clamp are to be installed on instrument at factory. Thread for clamping to mooring cable:
Clamp Size Note: Mooring wire is typically specified by wire size, not by outer diameter (O.D.) of the mooring wire jacket. Verify the wire jacket O.D. before selecting the clamp size. The clamp size must be less than or equal to the wire jacket O.D. but larger than the wire diameter. For example, Mooring System Inc.’s specifications for 3x19 wire rope (in 2016) are as follows:
For mounting on a rope, verify the rope outer diameter, and select a clamp smaller than the rope O.D. to account for the rope compressibility (for example, for 5/16 inch rope, select a ¼ inch clamp; a 5/16 inch clamp will be too large). |
||||||||||||||||||
50469.I | Wire guide & mounting clamp for 5/16 in. or 8 mm diameter mooring wire | |||||||||||||||||||
50470.I | Wire guide & mounting clamp for 3/8 in. diameter mooring wire | |||||||||||||||||||
50473.I | Wire guide & mounting clamp for 1/2 in. diameter mooring wire | |||||||||||||||||||
50467.I | Wire guide & mounting clamp for 6 mm diameter mooring wire | |||||||||||||||||||
50471.I | Wire guide & mounting clamp for 10 mm diameter mooring wire | |||||||||||||||||||
50474.I | Wire guide & mounting clamp for 12 mm diameter mooring wire | |||||||||||||||||||
50479.I | Alternative mounting - plastic brackets to provide through-bolt mounting to a flat surface | See document 67218. '.I' designation indicates that brackets are to be installed on instrument at factory. | ||||||||||||||||||
SeapHOx Spares & Accessories - See selections in SBE 37-SMP and SeaFET V2 | ||||||||||||||||||||
SeapHOx Integration Kits | ||||||||||||||||||||
50618 | SeapHOx™ V2 integration kit (mount brackets, flow tube adapter, Y-cable (MCBH SBE 37 connector), fasteners | These kits are intended for customers who already own a SeaFET™ and/or a MicroCAT and send their units to Sea-Bird for upgrade to a SeapHOx system. These kits are not intended for customers to perform the integration on their own. | ||||||||||||||||||
50637 | SeapHOx™ V2 integration kit (mount brackets, flow tube adapter, Y-cable (XSG SBE 37 connector), fasteners |