Seabird

SBE 19plus V2 SeaCAT Profiler CTD

SBE 19plus V2 SeaCAT Profiler CTD
The SBE 19plus V2 SeaCAT measures conductivity, temperature, and pressure at 4 scans/sec (4 Hz) and provides high accuracy and resolution, reliability, and ease-of-use for a wide range of research, monitoring, and engineering applications. Pump-controlled, T-C ducted flow minimizes salinity spiking caused by ship heave and allows for slow descent rates without slowing sensor responses, improving dynamic accuracy and resolving small scale structure in the water column. The 19plus V2 supports numerous auxiliary sensors (dissolved oxygen, pH, turbidity, fluorescence, oil, PAR, nitrates, altimeter, etc.) with six A/D channels and one RS-232 data channel. Data is recorded in memory and can also be output in real-time in engineering units or raw HEX. Nine alkaline D-cells provide power for up to 60 hours of profiling.

The 19plus V2 is commonly used autonomously, recording data internally. It can also provide real-time acquisition and display over short cables via the RS-232 interface; a load-bearing cable for hand-hauled, real-time profiling is available. External power and communication over 10,000 m of single-core, armored cable can be provided with the SBE 36 Deck Unit and PDIM. The 19plus V2 is easily integrated with a Sea-Bird Water Sampler; both real-time and autonomous auto-fire operations are possible.

In moored mode, the 19plus V2 records data at user-programmable intervals. This is easily configured with setup commands and by removing the profiling T-C Duct and installing optional anti-foulant devices.

FEATURES
• Conductivity, Temperature, Pressure, and up to seven auxiliary sensors.
• User-programmable mode: profiling at 4 Hz, or moored sampling at user-programmable intervals.
• RS-232 interface, internal memory, and internal alkaline batteries (can be powered externally).
• Pump-controlled, T-C ducted flow to minimize salinity spiking.
• Depths to 600, 7000, or 10,500 m.
• Seasoft© V2 Windows software package (setup, data upload, real-time data acquisition, and data processing).
• Next generation of the SeaCAT family, field-proven since 1987.
• Five-year limited warranty.

COMPONENTS
• Unique internal-field conductivity cell permits use of T-C Duct, minimizing salinity spiking.
• Aged and pressure-protected thermistor has a long history of exceptional accuracy and stability.
• Pressure sensor with temperature compensation is available in eight strain-gauge ranges (to 7000 m) and eleven Digiquartz® ranges (to 10,500 m). Note: Sampling rate 2 Hz when Digiquartz installed.
• Pump runs continuously (profiling mode), providing correlation of CTD and plumbed auxiliary sensor measurements.
 
Housing Pressure Sensor/Range Connectors Communications Pump
1 – 600 m (plastic) 1 – 20 m strain gauge 1 – XSG/AG 0 – RS-232 1 - SBE 5M
2 – 7000 m (titanium) 2 – 100 m strain gauge 2 – MCBH   2 - SBE 5P/5T
3 – 10,500 m (titanium) 3 – 350 m strain gauge      
  4 – 600 m strain gauge      
  5 – 1000 m strain gauge      
  6 – 2000 m strain gauge      
  7 – 3500 m strain gauge      
  8 – 7000 m strain gauge      
  9 – 10,500 m strain gauge      
  A – 45 psia Digiquartz      
  B – 100 psia Digiquartz      
  C – 200 psia Digiquartz      
  D – 300 psia Digiquartz      
  E – 400 psia Digiquartz      
  F – 1000 psia Digiquartz      
  G – 2000 psia Digiquartz      
  H – 3000 psia Digiquartz      
  I – 6000 psia Digiquartz      
  J – 10,000 psia Digiquartz      
  K – 15,000 psia Digiquartz      

Example: 19P.28201 is an SBE 19plus V2 with 7000 m housing, 7000 m strain gauge pressure sensor, MCBH connectors, RS-232 communications, and SBE 5M pump. See table below for description of each selection:

PART # DESCRIPTION NOTES
19plus V2

SeaCATplus Version 2 Profiler Pumped Conductivity, Temperature, Depth Recorder - 4 Hz sampling rate, includes submersible pump, 64 MB memory, 6 differential A/D channels (0 - 5 volt input range), 1 RS-232 data input channel, data I/O and pump Y-cable, 2.5 meter data I/O cable, Seasoft software, & complete documentation. Configurations that include pumped SBE 43 or other pumped auxiliary sensors require SBE 5T or 5P. Order protective cage separately.


19plus V2 in plastic housing with SBE 5M plastic pump & associated plumbing (plumbing configuration shown for 19plus V2 to be deployed in vertical orientation)

19plus V2 is intended primarily as a profiling CTD, sampling at 4 Hz, but can also be used in moored mode to obtain long-term time series data. 19plus V2 is powered by internal batteries, & records data in memory.

In addition, in profiling mode, 19plus V2 can be deployed:

  • With SBE 36 CTD Deck Unit & Power Data Interface Module (PDIM), which provide power & real-time data handling capability over single-conductor sea cables. For PDIM, specify 19p-9a or -9b .

  • With SBE 32 Carousel Water Sampler & SBE 33 Deck Unit, which provide power, real-time data handling capability, & real-time water sampler control over single-conductor sea cables. Order SBE 32 (32, 32C, or 32SC) & SBE 33 separately.

  • With SBE 32 Carousel Water Sampler & Auto Fire Module (AFM), which provide autonomous water sampling capability. Order SBE 32 (32, 32C, or 32SC) & AFM separately.

 

  • With SBE 55 ECO Water Sampler & SBE 33 Deck Unit, which provide power, real-time data handling capability, & real-time water sampler control over single-conductor sea cables. Order SBE 55 & SBE 33 separately.

  • With SBE 55 ECO Water Sampler, which has built-in capabilities similar to that of an SBE 32 integrated with an AFM, providing autonomous water sampling capability. Order SBE  55 separately.

Notes:

  • Optional auxiliary sensors on CTDs not shown.
  • (real-time systems) Computer, slip-ring-equipped winch, conductive cable, & NMEA 0183 navigation device not supplied by Sea-Bird.
  • (real-time systems) Seasave also supports acquisition of data from a NMEA device connected directly to computer (instead of deck unit).
SBE 19plus V2 Housing (depth) Selections MUST SELECT ONE
19P.1xx0x 600 m plastic housing  
19P.2xx0x 7000 m titanium housing  
19P.3xx0x 10,500 m titanium housing  
SBE 19plus V2 Pressure Sensor Selections MUST SELECT ONE
19P.x1x0x 20 m strain gauge pressure sensor Pressure sensor is installed in connector end cap, & is not field replaceable / swappable. While highest pressure rating gives you most flexibility in using 19plus V2, it is at expense of accuracy & resolution. It is advantageous to use lowest range pressure sensor compatible with your intended maximum operating depth, because accuracy & resolution are proportional to pressure sensor's full scale range. For example, comparing 2000 & 7000 m sensors:
  • 2000 m sensor:
    initial accuracy = 2 m (= 0.1% * 2000 m),
    resolution = 0.04 m (= 0.002% * 2000 m)
  • 7000 m sensor:
    initial accuracy = 7 m (= 0.1% * 7000 m),
    resolution = 0.14 m (= 0.002% * 7000 m)
19P.x2x0x 100 m strain gauge pressure sensor
19P.x3x0x 350 m strain gauge pressure sensor
19P.x4x0x 600 m strain gauge pressure sensor
19P.x5x0x 1000 m strain gauge pressure sensor
19P.x6x0x 2000 m strain gauge pressure sensor
19P.x7x0x 3500 m strain gauge pressure sensor
19P.x8x0x 7000 m strain gauge pressure sensor
19P.x9x0x 10,500 m strain gauge pressure sensor
19P.xAx0x 45 psia (20 m) Digiquartz pressure sensor with temperature compensation (2 Hz maximum sampling rate; longer housing than strain gauge version) Digiquartz pressure sensors provide better accuracy (0.02% of full scale range vs 0.1% of full scale range) & resolution (Digiquartz resolution dependent on user-programmable integration time) than strain gauge pressure sensors. See strain gauge options above for photo of pressure sensor port; when used with Digiquartz, nylon pressure capillary fitting screws into port.

Pressure sensor is installed in connector end cap, & is not field replaceable / swappable. While highest pressure rating gives you most flexibility in using 19plus V2, it is at expense of accuracy & resolution. It is advantageous to use lowest range pressure sensor compatible with your intended maximum operating depth, because accuracy & resolution are proportional to pressure sensor's full scale range. For example, comparing 2000 psia (1400 m) & 6000 psia (4200 m) sensors:

  • 2000 psia (1400 m) sensor:
    initial accuracy = 0.28 m (= 0.02% * 1400 m)
  • 6000 psia (4200 m) sensor:
    initial accuracy = 0.84 m (= 0.02% * 4200 m)

Note: 19plus V2 can only sample at 2 Hz (instead of 4 Hz) when equipped with Digiquartz pressure sensor. Additionally, 19plus V2 with Digiquartz pressure sensor is approximately 19 cm longer than strain gauge version, and requires a different cage (see PN 801270 under Spares & Accessories below).

19P.xBx0x 100 psia (60 m) Digiquartz pressure sensor with temperature compensation (2 Hz maximum sampling rate; longer housing than strain gauge version)
19P.xCx0x 200 psia (130 m) Digiquartz pressure sensor with temperature compensation (2 Hz maximum sampling rate; longer housing than strain gauge version)
19P.xDx0x 300 psia (200 m) Digiquartz pressure sensor with temperature compensation (2 Hz maximum sampling rate; longer housing than strain gauge version)
19P.xEx0x 400 psia (270 m) Digiquartz pressure sensor with temperature compensation (2 Hz maximum sampling rate; longer housing than strain gauge version)
19P.xFx0x 1000 psia (680 m) Digiquartz pressure sensor with temperature compensation (2 Hz maximum sampling rate; longer housing than strain gauge version)
19P.xGx0x 2000 psia (1,400 m) Digiquartz pressure sensor with temperature compensation (2 Hz maximum sampling rate; longer housing than strain gauge version)
19P.xHx0x 3000 psia (2,000 m) Digiquartz pressure sensor with temperature compensation (2 Hz maximum sampling rate; longer housing than strain gauge version)
19P.xIx0x 6000 psia (4,200 m) Digiquartz pressure sensor with temperature compensation (2 Hz maximum sampling rate; longer housing than strain gauge version)
19P.xJx0x 10,000 psia (6,800 m) Digiquartz pressure sensor with temperature compensation (2 Hz maximum sampling rate; longer housing than strain gauge version)
19P.xKx0x 15,000 psia (10,500 m) Digiquartz pressure sensor with temperature compensation (2 Hz maximum sampling rate; longer housing than strain gauge version)
SBE 19plus V2 Connector Selections MUST SELECT ONE
19P.xx10x XSG/AG connectors on SeaCAT bulkhead connectors, data I/O and pump Y-cable, and data I/O cable

Wet-pluggable connectors may be mated in wet conditions. Their pins do not need to be dried before mating. By design, water on connector pins is forced out as connector is mated. However, they must not be mated or un-mated while submerged. Wet-pluggable connectors have a non-conducting guide pin to assist pin alignment & require less force to mate, making them easier to mate reliably under dark or cold conditions, compared to XSG/AG connectors. Like XSG/AG connectors, wet-pluggables need proper lubrication & require care during use to avoid trapping water in sockets.

 
These selections include data I/O and pump Y-cable & data I/O cable compatible with data I/O - pump bulkhead connector.

19P.xx20x Wet-pluggable (MCBH) connectors on SeaCAT bulkhead connectors, data I/O and pump Y-cable, and data I/O cable
SBE 19plus V2 Submersible Pump Selections MUST SELECT ONE
19P.xxx01 SBE 5M pump

SBE 5M pump is intended for providing pumped conductivity only, for improved conductivity response over non-pumped configuration. SBE 5M pump with plastic housing is supplied for 19plus V2 with 600 m housing; SBE 5M pump with titanium housing is supplied for 19plus V2 with 7000 or 10,500 m housing.

Larger, more powerful SBE 5P or 5T is required if also planning to pump auxiliary sensors (such as dissolved oxygen, etc.). Operational characteristics of SBE 5P & 5T are identical. SBE 5P plastic pump is supplied for 19plus V2 with 600 m housing; SBE 5T titanium pump is supplied for 19plus V2 with 7000 or 10,500 m housing.

SBE 5M or 5P/5T selection includes pump (with same connector type as 19plus V2), pump mount, & data I/O - pump Y-cable (cable compatible with connectors on 19plus V2 and pump). See cable DN 31551 for XSG/AG connectors, DN 32896 for wet-pluggable connectors.

19P.xxx02 SBE 5P/5T pump
SBE 19plus V2 Auxiliary Sensor & Integration Options
19p-6a SBE 43 Dissolved Oxygen Sensor (Profiling Configuration), with XSG connector, 7000 m (cable & mount included, requires 19p-4b & 19P.xx10)

General Information:

  • 19p-6, -7, & -8 include auxiliary sensor, mount, & straight cable to connect sensor to 19plus V2 bulkhead connector. See auxiliary sensor specification sheets (SBE 43, 18, 27) for sensor descriptions. Auxiliary sensor connector type (XSG/AG or wet-pluggable) must match 19plus V2 connector type.
  • If connecting 2 sensors to 1 bulkhead connector, YMOLD (to create a y-cable) applies in addition to 19p-6, -7, & -8 price.
  • Additional sensors not listed here — fluorometers, transmissometers, turbidity meters, PAR sensors, etc. from third party manufacturers — are compatible with 19plus V2. These sensors can be purchased from Sea-Bird & integrated with 19plus V2 at our factory, or you can purchase mount kits & cables from Sea-Bird & perform integration yourself. See Third Party portion of price list.
  • User can change sensors on 19plus V2 in field. However, as noted above, Y-cable is required to connect 2 auxiliary sensors to 1 bulkhead connector on 19plus V2; each Y-cable is unique to sensors being integrated, so changing sensors may require changing Y-cable. In addition, sensor mechanical mountings may need to be changed to suit selected combination of sensors.

Sensor-Specific Information:

  • SBE 43 — SBE 43 is available in 7000 m titanium (19p-6a or -6b) or 600 m plastic (19p-6c or -6d) housing. SBE 43 is plumbed between conductivity sensor & pump. Consequently, system requires more powerful SBE 5P plastic or 5T titanium pump instead of 5M pump; operational characteristics of SBE 5P & 5T are identical.
  • SBE 18 & SBE 27 — Note that these sensors are only available with a depth rating to 1200 m.

Moored Application Information:

  • SBE 43 — If intending to use 19plus V2 in moored application, contact Sea-Bird to specify integration with an SBE 43 in Moored Configuration instead of Profiling Configuration (1 mil membrane vs 0.5 mil membrane for enhanced long-term stability; & black Tygon tubing vs clear Tygon tubing for plumbing, for reduced bio-fouling). Alternatively, we recommend use of the SBE  63 Optical Dissolved Oxygen Sensor for moored applications.
  • SBE 18 & SBE 27 — Sensors are not recommended for use in moored applications. See Application Note 76: pH or pH/ORP Sensors and Moored Applications.
19p-6b SBE 43 Dissolved Oxygen Sensor (Profiling Configuration), with Wet-pluggable connector, 7000 m (cable & mount included, requires 19p-4b & 19P.xx20)
19p-6c SBE 43 Dissolved Oxygen Sensor (Profiling Configuration), with XSG connector, 600 m plastic (cable & mount included, requires 19p-4a or -4b & 19P.xx10)
19p-6d SBE 43 Dissolved Oxygen Sensor (Profiling Configuration) with Wet-pluggable connector, 600 m plastic (cable & mount included, requires 19p-4a or -4b & 19P.xx20)
19p-7a SBE 18 pH sensor, for use in profiling mode only, with XSG connector, 1200 meter (cable and mount included; requires 19P.xx10)
19p-7b SBE 18 pH sensor, for use in profiling mode only, with Wet-pluggable connector, 1200 meter (cable and mount included; requires 19P.xx20)
19p-8a SBE 27 pH/ORP sensor, for use in profiling mode only, with AG connector, 1200 meter (cable and mount included; requires 19P.xx10)
19p-8b SBE 27 pH/ORP sensor, for use in profiling mode only, with Wet-pluggable connector, 1200 meter (cable and mount included; requires 19P.xx20)
YMOLD Extra charge for Y-cable to connect two (2) or more sensors to one (1) auxiliary sensor input bulkhead connector on CTD
19p-9a Underwater power/data interface module ( PDIM) with XSG connectors, integrated for use with SBE 36 CTD Deck Unit or 33 Carousel Deck Unit (includes PDIM, interface cable, and mounting hardware; requires 19P.xx10)

SBE 36 CTD Deck Unit & PDIM provide surface power & real-time data acquisition & control for 19plus V2, allowing deployment with 10,000 m long single-conductor sea cables. SBE 36 is installed on ship, while PDIM is mounted on or near 19plus V2.

SBE 33 Deck Unit is typically used to provide surface power & real-time data acquisition & control for 19plus V2 & SBE 32 (32, 32C, or 32SC) Carousel Water Sampler or SBE 55 ECO Water Sampler. However, it can be used with PDIM instead of Carousel or ECO to provide same functionality as SBE 36 & PDIM.

PDIM housing is anodized aluminum, & is rated to 6800 m. PDIM connector type (XSG or wet-pluggable) must match 19plus V2 connector type.

19p-9a & -9b do not include SBE 36 or 33 Deck Unit; order separately.

 
Can substitute SBE 33 Carousel Deck Unit for SBE 36 CTD Deck Unit.

19p-9b Underwater power/data interface module ( PDIM) with Wet-pluggable connectors, integrated for use with SBE 36 CTD Deck Unit or 33 Carousel Deck Unit (includes PDIM, interface cable, and mounting hardware; requires 19P.xx20)
SBE 19plus V2 Spares & Accessories
801269
Buy Now
Stainless-steel protective cage, 40 in. (101 cm) tall (SeaCATplus) Many users purchase optional cage to protect system from damage during deployment.
  • 801269 (drawing 22009) — cage for 19plus V2 with strain-gauge pressure sensor
  • 801270 (drawing 22010) — cage for 19plus V2 with Digiquartz pressure sensor (Digiquartz sensor requires longer 19plus V2 housing, which requires a taller cage)
  • 50396 (drawing 20893) — cage for 19plus V2 with strain gauge pressure sensor, mounted horizontally in extension stand below SBE 32 (full size) Carousel Water Sampler (requires shorter cage).
    Note: For 19plus V2 with Quartz pressure sensor, contact Sea-Bird.

See document 67171 for installation details.

Notes:

  • 801269 and 801270 are for use with SBE 19plus or 19plus V2, but not with older SeaCAT (SBE 19).
  • 19plus V2 deployed on SBE 32C (compact) or 32SC (subcompact) Carousel Water Sampler is mounted in bottle position on Carousel, & does not use cage.
  • 19plus V2 deployed on SBE 55 ECO Water Sampler is mounted on mesh panel, & does not use cage.
  • For cage with small footprint, typically used for deployment through ice, see drawing 22149 and photo on Gallery tab.
801270
Buy Now
Stainless-steel protective cage, 48 in. (123 cm) tall (SeaCATplus with Digiquartz)
50396
Buy Now
Stainless-steel protective cage, 38 in. (96 cm) tall, used in SBE 32 Carousel CTD extension stand
50434
Buy Now
SBE 16plusV2/19plusV2 Spares Kit ( XSG/AG connectors) - Complete support kit containing spare data I/O cable, bulkhead connectors, dummy plugs, Triton X-100, o-ring lubricant, & other mechanical spares & maintenance items. Order appropriate spares kit for connector type on 19plus V2:
  • 50434 for 19plus V2 with XSG/AG connectors — See document 67196.
  • 50435 for 19plus V2 with wet-pluggable connectors — See document 67197.
50435
Buy Now
SBE 16plusV2/19plusV2 Spares Kit ( Wet-pluggable connectors) - Complete support kit containing spare data I/O cable, bulkhead connectors, dummy plugs, Triton X-100, o-ring lubricant, & other mechanical spares & maintenance items.
801511 9 NiMH cells in rechargeable drop-in pack (108v/8.0 Ah)

19plus V2 comes standard with alkaline batteries, but can be powered with rechargeable NiMH batteries instead. Batteries are easily accessed by unscrewing battery end cap.

      
90900S
Buy Now
NiMH Battery Charger for 6, 9, or 12-cell/8.0 Ah D-cell packs. Provides full recharge in 2 hours, includes AC power cord and battery charging cable.
50288

SBE 19plus/19plusV2 Moored Mode Conversion Kit - anti-foulant holders and hardware for user conversion from profiling to moored mode configuration. AF24173 anti-foulant devices (PN 801542) are NOT included. Note: When installed on 19plus/19plusV2 at time of order, the T-C Duct and related parts normally installed on profilers are provided as a separate Profiling Conversion Kit, PN 50345 (order 801542 anti-foulant devices separately)

19plus V2 is intended primarily for use as profiling instrument, & does not come standard with anti-foulant device fittings. Conversion kit allows user to retrofit 19plus V2 with anti-foulant device fittings for moored applications. Anti-foulant device fittings attach to each end of conductivity cell. See document 67114. Only 1 conversion kit is needed per instrument; order replacement Anti-Foulant Devices as needed (see next item).
801542 AF24173 Anti-Foulant Device pair (spare, bagged, labeled for shipping) Anti-foulant devices fit into anti-foulant device cups at each end of conductivity cell. Anti-foulant devices included with standard shipment; these are spares.
Useful life varies, depending on several factors. We recommend that customers consider more frequent replacement when high biological activity & strong current flow (greater dilution of anti-foulant concentration) are present. Moored instruments in high growth & strong dilution environments have been known to obtain a few months of quality data, while drifters that operate in non-photic, less turbid deep ocean environments may achieve years of quality data. Experience may be strongest determining factor in specific deployment environments.
20200 USB to Serial Port Adapter, FTDI UC232R-10 (connects computers with USB ports to RS-232 instruments) Many newer PCs & laptop computers have USB port(s) instead of RS-232 serial port(s). USB serial adapter plugs into USB port, & allows a serial device to be connected through adapter. Multi-port adapters are available from other companies; see Application Note 68.
31634 Hardigg shipping case (AL4915-1105), for SBE 19plus/19plus V2 in optional cage Hardigg shipping case with custom foam inserts holds SBE 19plus V2 with auxiliary sensors in optional cage ( SBE 9plus shown; SBE 19plus V2 similar).
  • Rotationally molded high-impact polyethylene with reinforced corners & edges, molded-in corrugations, reinforced corners & edges, tongue-in-groove seal, positive anti-shear locks, comfort-grip handle, recessed hardware. Meets airline luggage regulations.
  • Inner dimensions:
    49 x 14.8 x 16.2 inches (124 x 38 x 41 cm).
  • Outer dimensions:
    52 x 17.8 x 18.4 inches (132 x 45 x 47 cm).

Order 31634 for 19plus V2 with strain-gauge pressure sensor; order 31842 for 19plus V2 with Digiquartz pressure sensor (19plus V2 with Digiquartz requires a longer cage - PN 801270 - which does not fit in PN 31634 shipping case).

Notes regarding features of Hardigg case supplied by Sea-Bird:
1. Case does not have wheels, because we prefer that the case is not rolled along the ground:
- Rolling along the ground could cause unnecessary vibration of the CTD.
- Rolling over a curb could cause unnecessary impact to the CTD.
2. Case has small holes on each metal latch, into which you could insert a small, TSA-approved lock or some zip ties. Case cannot accommodate a large padlock.

31842 Hardigg shipping case (AL6815-1105), for SBE 19plus/19plus V2 with Digiquartz in optional cage
50275
Buy Now
SBE 19plus/19plus V2 magnetic switch assembly Replacement for magnetic switch, which is used to start & stop logging. See document 67101.
41124
Buy Now
Battery cover/contact plate, replaces 80076.1 Cover plate for alkaline batteries.
801385 Data I/O cable, RMG-4FS with DB-9S & power leads, 2.4 m (DN 32277)

These test cables are used for setting up system & uploading data from memory after recovery. Data I/O cable connects to 4-pin end of pump-data I/O Y-cable.

Connector type (RMG or wet-pluggable) must match 19plus V2 connector type. Applicable cable is included with 19plus V2; these are spares.

801374 Data I/O cable, Wet-pluggable (MCIL-4FS) with DB-9S, 2.4 m (DN 32715)
17709 Y-cable, Pump-Data I/O, XSG/AG connectors (DN 31551)

These Y-cables connect 6-pin data I/O - pump bulkhead connector to pump (2-pin leg) & to data I/O cable (4-pin leg).

Connector type (XSG/AG or wet-pluggable) must match 19plus V2 connector type. Applicable cable is included with 19plus V2; these are spares.

171883 Y-cable, Pump-Data I/O, Wet-pluggable connectors (DN 32896)
23170
Buy Now
Seacat/Searam battery endcap handle (DN 20220)  
23114
Buy Now
Seacat/Searam battery endcap lifting eye (DN 20217)  
231787 Seacat connector guard, titanium (DN 21910) Typically used for SBE 19plus V2 deployed without a cage.
90087
Buy Now
Universal plumbing kit (includes pump air release valve, Y-fitting, & tubing) - Application Note 64-1 Application Note 64-1 details installation of plumbing for SBE 43 & pump on a CTD.
30411 Triton X-100 cleaning solution, 500 ml bottle  
50087
Buy Now
Cell filler/storage device with hose barbs ( Application Note 34) For cleaning conductivity cell after each use & storing instrument between uses. See document 67043 & Application Note 2D: Instructions for Care and Cleaning of Conductivity Cells.
various Plumbing For assorted sizes of Tygon tubing, see SBE 5M or 5P or 5T Configuration.
Underwater Cable for Hand-Hauled, Real-Time Profiling (see Application Note 59 for proper use and limitations)
801150 Load-bearing Data cable, XSG connector with DB-9S, 100 feet (30 m) (DN 32284)

These cables are for hand-hauling 19plus V2 & acquiring real-time data. Cables are not intended for static working loads above 45 kg (100 lbs); working loads above 18 kg (40 lbs) may be difficult to handle without winch. Minimum recommended cable bend radius is 10 cm (4 in.) (e.g., 20 cm sheave block nominal diameter). See Application Note 59: A Load-Bearing Underwater Cable for Hand-Hauled, Real-Time Profiling.

Select a cable with connector (XSG or wet-pluggable MCBH) to match your 19plus V2.

801295 Load-bearing Data cable, XSG connector with DB-9S, 165 feet (50 m) (DN 32284)
801140 Load-bearing Data cable, XSG connector with DB-9S, 200 feet (61 m) (DN 32284)
801153 Load-bearing Data cable, XSG connector with DB-9S, 330 feet (100 m) (DN 32284)
801301 Load-bearing Data cable, XSG connector with DB-9S, 415 feet (126 m) (DN 32284)
801148 Load-bearing Data cable, XSG connector with DB-9S, 600 feet (183 m) (DN 32284)
801371 Load-bearing Data cable, Wet-pluggable with DB-9S, 100 feet (30 m) (DN 32643)
801372 Load-bearing Data cable, Wet-pluggable with DB-9S, 200 feet (60 m) (DN 32643)
801337 Load-bearing Data cable, Wet-pluggable with DB-9S, 330 feet (100 m) (DN 32643)
801338 Load-bearing Data cable, Wet-pluggable with DB-9S, 660 feet (200 m) (DN 32643)