Seabird

SBE 5T/5P Submersible Pump

SBE 5T/5P Submersible Pump
Product #: SBE5T_5PSUBMERSIBLEPUMP
Unit Price Get Quote
Family Model Housing Connector Voltage RPM Duty Factory Set
05 M  1 – 600 m (plastic) 1 – XSG n/a n/a 1 – Pulsed Yes
2 – 10,500 m (titanium) 2 – MCBH n/a n/a 2 – Continuous  
P 1 – 600 m (plastic) 1 – XSG 1 – Standard 1 – 1300 0 – Fast (SBE CTDs)  
T 2 – 10,500 m (titanium) 2 – MCBH 2 – Low 2 – 2000 1 – Slow (non-SBE applications)  
      3 – 3000    
      4 – 4500    
SBE 5M Miniature Pump

Example: 05M.112x is an SBE 5M with 600 m housing, XSG connector, and continuous duty. See table below for description of each selection:

PART # DESCRIPTION NOTES
5M Miniature Submersible Pump - Centrifugal impeller, brush DC motor. Includes complete documentation. SBE 5M is standard pump supplied with SBE 19plus V2 CTD or optionally with 16plus V2 or 16plus-IM V2 to provide pumped conductivity.
If system includes dissolved oxygen &/or other pumped sensors, order more powerful SBE 5T or 5P (10,500 m titanium housing or 600 m plastic housing, respectively) instead.
SBE 5M Housing (Depth) Selections Option — MUST SELECT ONE    
05M.1xxx 600 m plastic housing  
05M.2xxx 10,500 m titanium housing  
SBE 5M Connector Selections — MUST SELECT ONE
05M.x1xx XSG connector

Wet-pluggable connectors may be mated in wet conditions. Their pins do not need to be dried before mating. By design, water on connector pins is forced out as connector is mated. However, they must not be mated or un-mated while submerged. Wet-pluggable connectors have a non-conducting guide pin to assist pin alignment & require less force to mate, making them easier to mate reliably under dark or cold conditions, compared to XSG/AG connectors. Like XSG/AG connectors, wet-pluggables need proper lubrication & require care during use to avoid trapping water in sockets.

05M.x2xx Wet-pluggable (MCBH) connector
SBE 5M Duty Selections — MUST SELECT ONE
05M.xx1x For use with SBE 16/16plus/16plus V2 ( powered off between samples) For 16/16plus/16plus-IM/ 16plus V2/ 16plus-IM V2, pump runs for 0.5 sec or more (depending on user setup) for each sample, & turns off between samples. SBE 16 family CTDs are integrated with SBE 5M with this Duty selection.
05M.xx2x For use with SBE 19/19plus/19plus V2 ( continuous duty) For 19/19plus/ 19plus V2 in Profiling mode, pump runs continuously while sampling. For 19plus/19plus V2 in Moored mode, pump runs for 0.5 sec or more (depending on user setup) for each sample, & turns off between samples. Because SBE 19 family CTDs are generally intended for use as profiling instrument, they are usually integrated with SBE 5M with this Duty selection.
SBE 5M Pump Spares & Accessories (For cables to connect SBE 5M to Sea-Bird CTD, see CTD listing SBE 16plus V2, 16plus-IM V2, 19plus V2.)
50062 Pump housing O-ring kit (document 67029)

See Application Note 75: Maintenance of SBE 5T, 5P, and 5M Pumps for additional details & parts that may be needed for pump maintenance.

50391 includes: 30009 pump impeller, 30010 pump thrust washer, 30095 O-ring, 30571 O-ring, 31011 O-ring.


Note: 235357 (black pump head) replaced 23593 (white pump head) in November 2015, and is backwards compatible with 23593.

50391 Pump impeller replacement kit (includes impeller, thrust washer, o-rings)
235357 SBE 5T/5M/5P Pump head (DN 235357)
23337 Air bleed valve, pump plumbing

Air bleed valve (inside Y-fitting) allows air in plumbing to escape, for profiling CTD (SBE 19/19plus/ 19plus V2) deployed in vertical orientation. If pump motor turns on when there is air in impeller housing, priming is uncertain & proper flow rate cannot be ensured.

30387 1/2" nylon hose barb Y-fitting
30388 Tygon tubing, 1/2" ID X 3/4" OD, 2 m — main plumbing Main plumbing, attaches to pump, conductivity sensor, 1/2" nylon hose barb Y-fitting, etc.
31450 Tygon tubing, 1/2" ID X 3/4" OD, 2 m, Black — main plumbing, minimizes light exposure 31450 can be used in place of 30388 to minimize exposure to light, improving resistance to bio-fouling for moored applications. Sea-Bird uses black tubing on all moored instruments (SBE 16plus/ 16plus V2 and 16plus-IM/ 16plus-IM V2 CTDs) that are integrated with SBE 43 Dissolved Oxygen Sensor. Customers may field retrofit plumbing on existing systems.
30385 Tygon tubing, 1/4" ID X 3/8" OD, 2 m — part of conductivity cell filling/storage device PN 50087 30385 is part of conductivity cell filling & storage device (50087), connects syringe to plastic reducing union. See Application Note 34: Instructions for Use of Conductivity Cell Filling and Storage Device PN 50087 and 50087.1 & Application Note 2D: Instructions for Care and Cleaning of Conductivity Cells.
SBE 5T Titanium Pump

Example: 05T.21120 is an SBE 5T with 10,500 m housing, XSG connector, Standard voltage, 2000 RPM, and Fast start duty. See table below for description of each selection:

PART # DESCRIPTION NOTES
05 P. 1xxxx Plastic Submersible Pump - Constant speed, centrifugal impeller, brushless DC motor, 600 m plastic housing. Includes complete documentation.

SBE 5P is standard pump supplied with plastic SBE 25 or 25plus CTD to provide pumped conductivity for deployments up to 600 m; also provides for other pumped sensors — dissolved oxygen, etc. SBE 5P is supplied optionally with 16plus V2, 16plus-IM V2, or 19plus V2 if system includes dissolved oxygen &/or other pumped sensors.

05 T. 2xxxx Titanium Submersible Pump - Constant speed, centrifugal impeller, brushless DC motor, 10,500 m titanium housing. Includes complete documentation.

SBE 5T is standard pump supplied with SBE 9plus CTD or aluminum SBE 25 or 25plus CTD to provide pumped conductivity for deployments up to 10,500 m; also provides for other pumped sensors — dissolved oxygen, etc. SBE 5T is supplied optionally with 16plus V2, 16plus-IM V2, or 19plus V2 if system includes dissolved oxygen &/or other pumped sensors.

SBE 5P/5T Connector Selections — MUST SELECT ONE
05x.x1xxx XSG connector Wet-pluggable connectors may be mated in wet conditions. Their pins do not need to be dried before mating. By design, water on connector pins is forced out as connector is mated. However, they must not be mated or un-mated while submerged. Wet-pluggable connectors have a non-conducting guide pin to assist pin alignment & require less force to mate, making them easier to mate reliably under dark or cold conditions, compared to XSG/AG connectors. Like XSG/AG connectors, wet-pluggables need proper lubrication & require care during use to avoid trapping water in sockets.
    
XSG connector on left; MCBH on right
05x.x2xxx Wet-pluggable (MCBH) connector
SBE 5P/5T Voltage Selections — MUST SELECT ONE
05x.xx1xx Standard voltage (typical for integration with SBE 9plus, 16plus, 16plus V2, 16plus-IM, 16plus-IM v2, 19plus, 19plus V2, 25plus)  
05x.xx2xx Low voltage (typical for integration with SBE 16 [not plus], 19 [not plus], 25 [not plus])  
SBE 5P/5T RPM Selections — MUST SELECT ONE
05x.xxx1x 1300 RPM  
05x.xxx2x 2000 RPM (typical for integration with SBE 16, 16plus, 16plus V2, 16plus-IM, 16plus-IM V2, 19, 19plus, 19plus V2, 25, 25plus)  
05x.xxx3x 3000 RPM (typical for integration with SBE 9plus)  
05x.xxx4x 4500 RPM  
SBE 5P/5T Start Duty Selections — MUST SELECT ONE
05x.xxxx0 Fast start (typical for integration with all Sea-Bird CTDs)  
05x.xxxx1 Slow start (typical for integration with any non-Sea-Bird instrument)  
SBE 5P & 5T Pump Spares & Accessories (For cables to connect pump to Sea-Bird CTD, see CTD listing SBE 16plus V2, 16plus-IM V2, 19plus V2.)
50062 Pump housing O-ring kit (document 67029)

See Application Note 75: Maintenance of SBE 5T, 5P, and 5M Pumps for additional details & parts that may be needed for pump maintenance.

50391 includes: 30009 pump impeller, 30010 pump thrust washer, 30095 O-ring, 30571 O-ring, 31011 O-ring.

  
Note: 235357 (black pump head) replaced 23593 (white pump head) in November 2015, and is backwards compatible with 23593.

50391 Pump impeller replacement kit (includes impeller, thrust washer, o-rings)
235357 SBE 5T/5M/5P Pump head (DN 235357)
23594 Pump end cap retainer (pre-2011 SBE 5T pumps)  
23337 Air bleed valve, pump plumbing Air bleed valve (inside Y-fitting) allows air in plumbing to escape, for profiling CTD (SBE 19/19plus/ 19plus V2) deployed in vertical orientation. If pump motor turns on when there is air in impeller housing, priming is uncertain & proper flow rate cannot be ensured.
30387 1/2" nylon hose barb Y-fitting
30388 Tygon tubing, 1/2" ID X 3/4" OD, 2 m — main plumbing Main plumbing, attaches to pump, conductivity sensor, 1/2" nylon hose barb Y-fitting, etc.
31450 Tygon tubing, 1/2" ID X 3/4" OD, 2 m, Black — main plumbing, minimizes light exposure 31450 can be used in place of 30388 to minimize exposure to light, improving resistance to bio-fouling for moored applications. Sea-Bird uses black tubing on all moored instruments (SBE 16plus/ 16plus V2 and 16plus-IM/ 16plus-IM V2 CTDs) that are integrated with SBE 43 Dissolved Oxygen Sensor. Customers may field retrofit plumbing on existing systems.
30385 Tygon tubing, 1/4" ID X 3/8" OD, 2 m — part of conductivity cell filling/storage device PN 50087 30385 is part of conductivity cell filling & storage device (50087), connects syringe to plastic reducing union. See Application Note 34: Instructions for Use of Conductivity Cell Filling and Storage Device PN 50087 and 50087.1 & Application Note 2D: Instructions for Care and Cleaning of Conductivity Cells.
30382 Tygon tubing, 1/4" ID X 5/16" OD, 2 m — connects T duct to C duct Connects T duct to C duct for SBE 3 & 4C on SBE 9plus, 25, or 25plus CTD.
30384 Tygon tubing, 7/16" ID X 9/16" OD, 2 m — cell soaker tubing for SBE 4 Cell soaker tubing for SBE 4M or 4C Conductivity Sensor, used when storing sensor dry (to keep out dust & debris) or with Triton solution. This thin-walled (1/16") tubing is more flexible than main plumbing tubing, 30388, allowing for tighter tubing bends. See Application Note 2D: Instructions for Care and Cleaning of Conductivity Cells.
30579 Tygon tubing, 3/8" ID X 1/2" OD, 2 m — fits over ends of SBE 43 plenum Small piece of 30579 Tygon tubing fits over ends of SBE 43 Dissolved Oxygen Sensor plenum. Main plumbing tubing (30388) fits over 30579.
SBE 5P Plastic Pump

Example: 05T.21120 is an SBE 5T with 10,500 m housing, XSG connector, Standard voltage, 2000 RPM, and Fast start duty. See table below for description of each selection:

PART # DESCRIPTION NOTES
05 P. 1xxxx Plastic Submersible Pump - Constant speed, centrifugal impeller, brushless DC motor, 600 m plastic housing. Includes complete documentation.

SBE 5P is standard pump supplied with plastic SBE 25 or 25plus CTD to provide pumped conductivity for deployments up to 600 m; also provides for other pumped sensors — dissolved oxygen, etc. SBE 5P is supplied optionally with 16plus V2, 16plus-IM V2, or 19plus V2 if system includes dissolved oxygen &/or other pumped sensors.

05 T. 2xxxx Titanium Submersible Pump - Constant speed, centrifugal impeller, brushless DC motor, 10,500 m titanium housing. Includes complete documentation.

SBE 5T is standard pump supplied with SBE 9plus CTD or aluminum SBE 25 or 25plus CTD to provide pumped conductivity for deployments up to 10,500 m; also provides for other pumped sensors — dissolved oxygen, etc. SBE 5T is supplied optionally with 16plus V2, 16plus-IM V2, or 19plus V2 if system includes dissolved oxygen &/or other pumped sensors.

SBE 5P/5T Connector Selections — MUST SELECT ONE
05x.x1xxx XSG connector Wet-pluggable connectors may be mated in wet conditions. Their pins do not need to be dried before mating. By design, water on connector pins is forced out as connector is mated. However, they must not be mated or un-mated while submerged. Wet-pluggable connectors have a non-conducting guide pin to assist pin alignment & require less force to mate, making them easier to mate reliably under dark or cold conditions, compared to XSG/AG connectors. Like XSG/AG connectors, wet-pluggables need proper lubrication & require care during use to avoid trapping water in sockets.
    
XSG connector on left; MCBH on right
05x.x2xxx Wet-pluggable (MCBH) connector
SBE 5P/5T Voltage Selections — MUST SELECT ONE
05x.xx1xx Standard voltage (typical for integration with SBE 9plus, 16plus, 16plus V2, 16plus-IM, 16plus-IM v2, 19plus, 19plus V2, 25plus)  
05x.xx2xx Low voltage (typical for integration with SBE 16 [not plus], 19 [not plus], 25 [not plus])  
SBE 5P/5T RPM Selections — MUST SELECT ONE
05x.xxx1x 1300 RPM  
05x.xxx2x 2000 RPM (typical for integration with SBE 16, 16plus, 16plus V2, 16plus-IM, 16plus-IM V2, 19, 19plus, 19plus V2, 25, 25plus)  
05x.xxx3x 3000 RPM (typical for integration with SBE 9plus)  
05x.xxx4x 4500 RPM  
SBE 5P/5T Start Duty Selections — MUST SELECT ONE
05x.xxxx0 Fast start (typical for integration with all Sea-Bird CTDs)  
05x.xxxx1 Slow start (typical for integration with any non-Sea-Bird instrument)  
SBE 5P & 5T Pump Spares & Accessories (For cables to connect pump to Sea-Bird CTD, see CTD listing SBE 16plus V2, 16plus-IM V2, 19plus V2.)
50062 Pump housing O-ring kit (document 67029)

See Application Note 75: Maintenance of SBE 5T, 5P, and 5M Pumps for additional details & parts that may be needed for pump maintenance.

50391 includes: 30009 pump impeller, 30010 pump thrust washer, 30095 O-ring, 30571 O-ring, 31011 O-ring.

  
Note: 235357 (black pump head) replaced 23593 (white pump head) in November 2015, and is backwards compatible with 23593.

50391 Pump impeller replacement kit (includes impeller, thrust washer, o-rings)
235357 SBE 5T/5M/5P Pump head (DN 235357)
23594 Pump end cap retainer (pre-2011 SBE 5T pumps)  
23337 Air bleed valve, pump plumbing Air bleed valve (inside Y-fitting) allows air in plumbing to escape, for profiling CTD (SBE 19/19plus/ 19plus V2) deployed in vertical orientation. If pump motor turns on when there is air in impeller housing, priming is uncertain & proper flow rate cannot be ensured.
30387 1/2" nylon hose barb Y-fitting
30388 Tygon tubing, 1/2" ID X 3/4" OD, 2 m — main plumbing Main plumbing, attaches to pump, conductivity sensor, 1/2" nylon hose barb Y-fitting, etc.
31450 Tygon tubing, 1/2" ID X 3/4" OD, 2 m, Black — main plumbing, minimizes light exposure 31450 can be used in place of 30388 to minimize exposure to light, improving resistance to bio-fouling for moored applications. Sea-Bird uses black tubing on all moored instruments (SBE 16plus/ 16plus V2 and 16plus-IM/ 16plus-IM V2 CTDs) that are integrated with SBE 43 Dissolved Oxygen Sensor. Customers may field retrofit plumbing on existing systems.
30385 Tygon tubing, 1/4" ID X 3/8" OD, 2 m — part of conductivity cell filling/storage device PN 50087 30385 is part of conductivity cell filling & storage device (50087), connects syringe to plastic reducing union. See Application Note 34: Instructions for Use of Conductivity Cell Filling and Storage Device PN 50087 and 50087.1 & Application Note 2D: Instructions for Care and Cleaning of Conductivity Cells.
30382 Tygon tubing, 1/4" ID X 5/16" OD, 2 m — connects T duct to C duct Connects T duct to C duct for SBE 3 & 4C on SBE 9plus, 25, or 25plus CTD.
30384 Tygon tubing, 7/16" ID X 9/16" OD, 2 m — cell soaker tubing for SBE 4 Cell soaker tubing for SBE 4M or 4C Conductivity Sensor, used when storing sensor dry (to keep out dust & debris) or with Triton solution. This thin-walled (1/16") tubing is more flexible than main plumbing tubing, 30388, allowing for tighter tubing bends. See Application Note 2D: Instructions for Care and Cleaning of Conductivity Cells.
30579 Tygon tubing, 3/8" ID X 1/2" OD, 2 m — fits over ends of SBE 43 plenum Small piece of 30579 Tygon tubing fits over ends of SBE 43 Dissolved Oxygen Sensor plenum. Main plumbing tubing (30388) fits over 30579.