A combination of precision optics and high performance microelectronics which can be operated as a stand-alone device or in a networked environment as a part of a larger system.

The OCR-500 Series Radiometers are fully digital optical sensors that combine precision optics and high performance microelectronics.  The radiometers may be operated as a stand-alone device or in a networked environment as part of a larger system.  These units are available in four or seven channel discrete wavelengths.  Choose channels from our standard stocked wavelengths.


Features:

  • Irradiance and Radiance sensors for in-water and in-air applications
  • Standard wavelengths from 400 - 865 nm
  • UV wavelengths available 305, 325, 340 & 380 nm
  • Fully characterized cosine response
  • Custom low fluorescence filters
  • Networking capability
  • Data logging and processing software included
  • Fast sampling rate (7 - 24 Hz optional)
  • Compatible with the Bioshutter anti-biofouling solution

View data taken with the Sea-Bird Scientific Mulitspectral Radiometers on the Boussole website.

OCR-500 SERIES IRRADIANCE SENSOR - STANDARD AND AUV SERIES

The OCR-500 micro-sensor series is a fully digital optical sensor package that combines precision optics and high performance microelectronics.  Satlantic designed this sensor series for applications where performance, size and power are key constraints. The OCR-500 series radiometers can be mounted on real-time profilers, moored, and autonomous deepwater buoys and autonomous underwater vehicles (AUV’s).


DOWNWELLING IRRADIANCE SENSOR MODEL OCR-504 / 507 / AUV

SPATIAL CHARACTERISTICS

Field of view In-air or in-water Cosine response (Spectrally corrected)
Collector Area 86.0 mm2
Detectors Custom 17 mm2 Silicon photodiodes

 

SPECTRAL CHARACTERISTICS

Bandwidth range 400 - 865 nm standard
Number of channels 4 or 7 channels
Spectral bandwidth 10 nm or 20 nm
Filter type Ion Assisted Deposition (IAD) Custom low fluorescence

 

OPTICAL CHARACTERISTICS

Out of band rejection 10-6
Cosine Response 3% from 0-60°
10% from 60-85°
Typical saturation 300 µW cm-2 nm-1
Typical Noise equivalent irradiance (NEI) 2.5 X10-3 µW cm-2 nm-1

 

TEMPORAL CHARACTERISTICS

System time constant 0.011 seconds

 

ELECTRICAL CHARACTERISTICS

Telemetry options RS232, RS422
Network options RS232, RS485 SATNET
Input voltage 6 to 22 VDC (12-volt nominal)
Current (4 and 7 channel) 25 mA @ 12VDC
40 mA at 12V

 

PHYSICAL CHARACTERISTICS

Height (4 and 7 channel) 11.0 cm, 12.5 cm
Diameter 4.6 cm, 6.5 cm
Weight
260 grams, 420 grams
Material Acetron/Anodized Aluminum
Connector (standard) Micro 8 pin male
Maximum depth

OCR-504 350 m (AcetronGP)
OCR-504 2000 m (PEEK)

OCR-504 UV 200 m (AcetronGP)

OCR-507 350 m (AcetronGP)
OCR-507 1000m (PEEK)

OCR-504 AUV 1000 m (Anodized Aluminum)
OCR-507 AUV 1000 m (Anodized Aluminum)

 

SYSTEM ELECTRONICS

Sample rate 7Hz (24 Hz optional)
A/D conversio 24 bit
Dynamic range 18 bit
Telemetry  RS232, RS422
Data format Binary
Baud rate User selectable from
9.6 to 115.2 kbps

 

OCR-500 SERIES RADIANCE SENSOR - STANDARD AND AUV SERIES

The OCR-500 micro-sensor series is a fully digital optical sensor package that combines precision optics and high performance microelectronics. Satlantic designed this sensor series for applications where performance, size and power are key constraints. The OCR-500 series radiometers can be mounted on real- time profilers, moored, and autonomous deepwater buoys and autonomous underwater vehicles (AUV’s).

UPWELLING RADIANCE SENSOR MODEL OCR-504 / 507/ AUV

 

SPATIAL CHARACTERISTICS

Field of view
 

10° in water (Half angle, half maximum)
14° in air (Half angle, half-maximum)

Entrance aperture 9.5 mm diameter
Detectors Custom 13 mm2 Silicon photodiodes

 

SPECTRAL CHARACTERISTICS

Bandwidth range 400 - 865 nm standard
Number of channels 4 or 7 channel
Spectral bandwidth 10 nm or 20 nm
Filter type Ion Assisted Deposition (IAD)
Custom low fluorescence

 

OPTICAL CHARACTERISTICS

Out of band rejection 10-6
Out of field rejection 5X10-4 >1.5 FOV
Typical saturation 5 µW cm-2 nm-1 1sr-1
Noise equivalent radiance (NER) 300 x10-3 µW cm-2 nm-1 sr-1

 

TEMPORAL CHARACTERISTICS

System time constant 0.011 seconds

 

ELECTRICAL CHARACTERISTICS

Telemetry options RS232, RS422
Network options SatNet RS485
Input voltage 25 mA @ 12VDC
Current (4 or 7 channel) 40 mA at 12V

 

PHYSICAL CHARACTERISTICS

Height (4 or 7 channel)
 
11.0 cm, 12.5 cm
Diameter (4 or 7 channel) 4.6 cm, 6.4 cm
Weight 260 grams, 400 grams
Housing Material Acetron / Anodized Aluminum
Connector (standard) Micro 8 pin male
Maximum depth

OCR-504 350 m (AcetronGP)
OCR-504 2000 m (PEEK)

OCR-504 UV 200 m (AcetronGP)

OCR-507 350 m (AcetronGP)
OCR-507 1000 m (PEEK)

OCR-504 AUV 1000 m(Anodized Aluminum)
OCR-507 AUV 1000 m (Anodized Aluminum)

 

SYSTEM ELECTRONICS

Sample rate 7Hz (24 Hz optional)
A/D conversion 24 bit
Dynamic range 18 bit
Telemetry RS232, RS422
Data format Binary
Baud rate User selectable from 9.6 to 115.2 kbps

Specifications may change without notice.


 

The list below includes (as applicable) the current product brochure, manual, and quick guide; software manual(s); and application notes.

Title Type Publication Date PDF File
Navis BGCi Brochure Product Brochure Wednesday, October 19, 2016 Navis-Biogeochemical-Profiling-Floats-2016.pdf
AN117 Standard Stocked Detector Wavelengths Application Notes Friday, June 23, 2017 standard-stocked-wavelengths.pdf
Navis Profiling Float Product Guide - Feature Comparisons Product Brochure Thursday, November 26, 2015 NavisProductGuideAPR2016.pdf
OCR Series Datasheet Product Datasheet Friday, June 23, 2017 datasheet-ocr-500-group.pdf
OCR 507 Manual Product Manual Thursday, June 22, 2017 Manual-OCR-507-SAT-DN-00027.pdf
OCR 504 UV Manual Product Manual Thursday, June 22, 2017 Manual-OCR-504UV-SAT-DN-00142.pdf
OCR 504 Manual Product Manual Monday, November 20, 2017 Manual-OCR-504-SAT-DN-00034.pdf
ProSoft User Manual Software Manual Wednesday, June 14, 2017 ProSoftUserManual7.7SAT-DN-00228.pdf
SatView Manual Software Manual Wednesday, June 14, 2017 SatView-Manual.pdf
SatCon Manual Software Manual Wednesday, March 9, 2011 SatCon-Manual.pdf

SatView is a real-time interactive data logging and display application for use with Sea-Bird radiometers. SatView makes it easy to connect to your Satlantic instruments and view time series, spectral plots, and depth profiles while capturing data for subsequent conversion and post-processing.

SatView features include:

Version 2.9.5 released April 11, 2014

SatView 2.9 provides Windows 7 compatibility, improved PAR sensor support, wavelength range settings for spectral views, additional cast card fields for post-processing, support for up to 96 serial ports, GPS data validation and many more. Please refer to the release notes for a detailed list of recent improvements.

SatView-2.9.5-b7-x86.exe for Windows 7/8/10


Version 7.7.19 released April 12, 2016

ProSoft 7.7.19 provides a number of key improvements including support for ancillary SAS sensors, support for  BETA_IRED and BETA_GREEN sensors to calculate backscattering, corrected backscattering coefficient units, robust handling of corrupt timer data, HyperSAS IR camera integration, interruptable processing, and more. For a detailed list of recent fixes and features, please refer to the release notes.

ProSoft7.7.19-b2_Setup.exe for Windows 7/8/10


SatCon is a software utility for converting raw binary data, as logged by SatView, into readable ASCII text suitable for import by third party applications such as spreadsheets or databases. Data can be extracted in calibrated physical units or raw binary counts. SatCon can be operated interactively through a user friendly graphical interface, or in batch mode as a background process.

For minimum system requirements, installation instructions, and new features, please refer to the release notes in the SatCon User Manual.

Version 1.5.5 released April 28, 2011
SatCon-1.5.5-b2-x86.exe for Windows 7/8/10


What are SIP files?

Files that are delivered with Sea-Bird Scientific and third party equipment to describe the sensors data output and calibration coefficients come in two types. Calibration files or *.cal files and telemetry definition format files or *.tdf files. In some cases, systems are created that network many sensors together and their combined data is provided in one serial output. The simplest example is a HOCR sensor that generates both light and dark frames. A more complex example is a HPROII profiling system that may contain as many as 5 sensors and 7 individual calibration and tdf files. These files must be used to both collect and process the data. This can become quite confusing to keep track of all these files so Sea-Bird Scientific developed SIP files. All CAL and TDF files required for a system are zipped using winzip and the extension changed from *.ZIP to *.SIP. The file name includes the system description (usually the network master serial number) and the creation date. This SIP file can then be used in place of individual files to collect and process data.

Bioshutter II

The Bioshutter II is an autonomous underwater shutter attachment designed for use with Satlantic radiometers. The primary purpose of the shutter is to prevent marine bio-fouling of the sensor optics in moored, time-series application. Copper, and copper-based alloys have long been known to have good resistance against bio fouling and have been used in a diverse variety of commercial applications. Scientists working at the University of California Santa Barbara Ocean Physics Lab under the auspices of the National Ocean Partnership Programs' (NOPP) Ocean System of Chemical, Optical, and Physical Experiments (O-SCOPE) project developed an underwater shutter device for use with instruments such as Satlantic's OCR-500 and HyperOCR series instruments. The Satlantic Bioshutter II device builds upon the success of this instrument by combining an innovative copper shutter and an input power controlled motor drive assembly to ensure robust operation in harsh marine environments.